-- --defines ALCOMA-MIB for SNMP agent extension --Contents: Global Registration Module -- ALCOMA OIDs - Enterprise 12140 --Version: 4.1 --Date: 2 December, 2010 --Developed By: ing.Václav VACEK -- sw. application engineer -- ALCOMA, spol. s r.o. -- --Copyright (c)2010 By ALCOMA, spol. s r.o. -- ALCOMA-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB; alcoma OBJECT IDENTIFIER ::= { enterprises 12140 } products OBJECT IDENTIFIER ::= { alcoma 1 } alMP OBJECT IDENTIFIER ::= { alcoma 2 } alRADIO-RELAY-LINK OBJECT IDENTIFIER ::= { products 1 } alNMS OBJECT IDENTIFIER ::= { products 2 } -- Power Source MIB -- Parameters (Prefix Par) alStatusLED OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 1 } alEHW OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Hardware error." ::= { alStatusLED 1 } alESR OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Signal error in radio." ::= { alStatusLED 2 } alESL OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Signal error on lines." ::= { alStatusLED 3 } alCA OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Non-standard command activate." ::= { alStatusLED 4 } local-station OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 2 } alL-General OBJECT IDENTIFIER ::= { local-station 1 } alLSupervisor OBJECT-TYPE SYNTAX INTEGER { offline(-1),none(0),terminal(1),local(2),network(3),service(4),alcoma(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Active supervisor." ::= { alL-General 1 } alLConfiguration OBJECT-TYPE SYNTAX INTEGER { offline(-1),undefined(0),cf2xE1(1),cf4xE1(2),cf1xE2(3),cf1xE1-Ethernet(4),cf1xE3-E1(7),cf1xEthernet(8), cf1xEthF-E1(9), cf1xEthF-E1-1xE1(10),cf1xEthF-E1-2xE1(11),cf1xEthF-E1-3xE1(12),cf1xEthF-E1-4xE1(13), cf1xEthF-E1-5xE1(14),cf1xEthF-E1-6xE1(15),cf1xEthF-E1-7xE1(16),cf1xEthF-E1-8xE1(17), cf1xEthF(18), cf1xEthF-1xE1(19),cf1xEthF-2xE1(20),cf1xEthF-3xE1(21),cf1xEthF-4xE1(22), cf1xEthF-5xE1(23),cf1xEthF-6xE1(24),cf1xEthF-7xE1(25),cf1xEthF-8xE1(26), cf2xFEth(27),cf2xFEth-1xE1(28), cf4xFEth-2xE1(29), cf2xGEth(30),cf2xGEth-SFP100(31),cf2xGEth-SFP1000(32),cf2xGEth-SFPSG(33) } ACCESS read-only STATUS mandatory DESCRIPTION "IDU configuration." ::= { alL-General 2 } alLStatus OBJECT-TYPE SYNTAX INTEGER { offline(0),ok(1),warning(2),error(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Station alarm status." ::= { alL-General 3 } alLHistory OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "History alarm status." ::= { alL-General 4 } alLIAISL OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Automatic AIS ignored." ::= { alL-General 5 } alLILEVPWR OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Low RX or TX level alarms ignored." ::= { alL-General 6 } alL-ODU OBJECT IDENTIFIER ::= { local-station 2 } alLRX-Level OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Signal receiver level." ::= { alL-ODU 1 } alLTX-PWR OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Transmitter power level." ::= { alL-ODU 2 } alLMode-TX OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),manual(1),atpc(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Mode of power control." ::= { alL-ODU 3 } alLODU-LB OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU line-loopback." ::= { alL-ODU 4 } alL-Modem OBJECT IDENTIFIER ::= { local-station 3 } alLQuality OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),out(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Quality of 4-level modulation." ::= { alL-Modem 1 } alL-Supply OBJECT IDENTIFIER ::= { local-station 4 } alLVoltage-5V OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),high(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage 5V high." ::= { alL-Supply 1 } alLVoltage-5Vor15V OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage 5V or 15V low." ::= { alL-Supply 2 } alLVoltage-24V OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage 24V low." ::= { alL-Supply 3 } alLCurrent-ODU OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),out(1) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU current range." ::= { alL-Supply 4 } alLInput OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Input voltage low." ::= { alL-Supply 5 } alL-IDU OBJECT IDENTIFIER ::= { local-station 5 } alLEEPROM OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "EEPROM memory status." ::= { alL-IDU 1 } alLRAM OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "RAM memory status." ::= { alL-IDU 2 } alLBattery OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "RAM backup battery voltage." ::= { alL-IDU 3 } alLCommIDU OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication status with blocks of IDU." ::= { alL-IDU 4 } alLCommRMT OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication status with remote station." ::= { alL-IDU 5 } alL-MUX OBJECT IDENTIFIER ::= { local-station 6 } alLBER-10E6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "BER > 10E-6." ::= { alL-MUX 1 } alLBER-10E4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "BER > 10E-4." ::= { alL-MUX 2 } alLFrame OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),loss(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Frame LOSS." ::= { alL-MUX 3 } alL-PDH1 OBJECT IDENTIFIER ::= { local-station 7 } alLPDHFrame OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),loss(1) } ACCESS read-only STATUS mandatory DESCRIPTION "PDH1 frame LOSS." ::= { alL-PDH1 1 } alLAISPDH OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to PDH1 frame." ::= { alL-PDH1 2 } alLLLBPDH OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on PDH1 frame." ::= { alL-PDH1 3 } alLRLBPDH OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on PDH1 frame." ::= { alL-PDH1 4 } alL-Line1 OBJECT IDENTIFIER ::= { local-station 9 } alLOSS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 1." ::= { alL-Line1 1 } alILOSS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 1." ::= { alL-Line1 2 } alAIS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 1." ::= { alL-Line1 3 } alAISL1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 1." ::= { alL-Line1 4 } alLLB1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 1." ::= { alL-Line1 5 } alRLB1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 1." ::= { alL-Line1 6 } alL-Line2 OBJECT IDENTIFIER ::= { local-station 10 } alLLOSS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 2." ::= { alL-Line2 1 } alLILOSS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 2." ::= { alL-Line2 2 } alLAIS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 2." ::= { alL-Line2 3 } alLAISL2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 2." ::= { alL-Line2 4 } alLLLB2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 2." ::= { alL-Line2 5 } alLRLB2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 2." ::= { alL-Line2 6 } alL-Line3 OBJECT IDENTIFIER ::= { local-station 11 } alLLOSS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 3." ::= { alL-Line3 1 } alLILOSS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 3." ::= { alL-Line3 2 } alLAIS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 3." ::= { alL-Line3 3 } alLAISL3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 3." ::= { alL-Line3 4 } alLLLB3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 3." ::= { alL-Line3 5 } alLRLB3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 3." ::= { alL-Line3 6 } alL-Line4 OBJECT IDENTIFIER ::= { local-station 12 } alLLOSS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 4." ::= { alL-Line4 1 } alLILOSS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 4." ::= { alL-Line4 2 } alLAIS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 4." ::= { alL-Line4 3 } alLAISL4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 4." ::= { alL-Line4 4 } alLLLB4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 4." ::= { alL-Line4 5 } alLRLB4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 4." ::= { alL-Line4 6 } alL-Line5 OBJECT IDENTIFIER ::= { local-station 13 } alLLOSS5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 5." ::= { alL-Line5 1 } alLILOSS5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 5." ::= { alL-Line5 2 } alLAIS5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 5." ::= { alL-Line5 3 } alLAISL5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 5." ::= { alL-Line5 4 } alLLLB5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 5." ::= { alL-Line5 5 } alLRLB5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 5." ::= { alL-Line5 6 } alL-Line6 OBJECT IDENTIFIER ::= { local-station 14 } alLLOSS6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 6." ::= { alL-Line6 1 } alLILOSS6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 6." ::= { alL-Line6 2 } alLAIS6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 6." ::= { alL-Line6 3 } alLAISL6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 6." ::= { alL-Line6 4 } alLLLB6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 6." ::= { alL-Line6 5 } alLRLB6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 6." ::= { alL-Line6 6 } alL-Line7 OBJECT IDENTIFIER ::= { local-station 15 } alLLOSS7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 7." ::= { alL-Line7 1 } alLILOSS7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 7." ::= { alL-Line7 2 } alLAIS7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 7." ::= { alL-Line7 3 } alLAISL7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 7." ::= { alL-Line7 4 } alLLLB7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 7." ::= { alL-Line7 5 } alLRLB7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 7." ::= { alL-Line7 6 } alL-Line8 OBJECT IDENTIFIER ::= { local-station 16 } alLLOSS8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 8." ::= { alL-Line8 1 } alLILOSS8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 8." ::= { alL-Line8 2 } alLAIS8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 8." ::= { alL-Line8 3 } alLAISL8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 8." ::= { alL-Line8 4 } alLLLB8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 8." ::= { alL-Line8 5 } alLRLB8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 8." ::= { alL-Line8 6 } alL-Line9 OBJECT IDENTIFIER ::= { local-station 17 } alLLOSS9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 9." ::= { alL-Line9 1 } alLILOSS9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 9." ::= { alL-Line9 2 } alLAIS9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 9." ::= { alL-Line9 3 } alLAISL9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 9." ::= { alL-Line9 4 } alLLLB9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 9." ::= { alL-Line9 5 } alLRLB9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 9." ::= { alL-Line9 6 } alL-Line10 OBJECT IDENTIFIER ::= { local-station 18 } alLLOSS10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 10." ::= { alL-Line10 1 } alLILOSS10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 10." ::= { alL-Line10 2 } alLAIS10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 10." ::= { alL-Line10 3 } alLAISL10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 10." ::= { alL-Line10 4 } alLLLB10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 10." ::= { alL-Line10 5 } alLRLB10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 10." ::= { alL-Line10 6 } alL-Line11 OBJECT IDENTIFIER ::= { local-station 19 } alLLOSS11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 11." ::= { alL-Line11 1 } alLILOSS11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 11." ::= { alL-Line11 2 } alLAIS11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 11." ::= { alL-Line11 3 } alLAISL11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 11." ::= { alL-Line11 4 } alLLLB11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 11." ::= { alL-Line11 5 } alLRLB11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 11." ::= { alL-Line11 6 } alL-Line12 OBJECT IDENTIFIER ::= { local-station 20 } alLLOSS12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 12." ::= { alL-Line12 1 } alLILOSS12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 12." ::= { alL-Line12 2 } alLAIS12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 12." ::= { alL-Line12 3 } alLAISL12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 12." ::= { alL-Line12 4 } alLLLB12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 12." ::= { alL-Line12 5 } alLRLB12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 12." ::= { alL-Line12 6 } remote-station OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 3 } alR-General OBJECT IDENTIFIER ::= { remote-station 1 } alRSupervisor OBJECT-TYPE SYNTAX INTEGER { offline(-1),none(0),terminal(1),local(2),network(3),service(4),alcoma(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Active supervisor." ::= { alR-General 1 } alRConfiguration OBJECT-TYPE SYNTAX INTEGER { offline(-1),undefined(0),cf2xE1(1),cf4xE1(2),cf1xE2(3),cf1xE1-Ethernet(4),cf1xE3-E1(7),cf1xEthernet(8), cf1xEthF-E1(9), cf1xEthF-E1-1xE1(10),cf1xEthF-E1-2xE1(11),cf1xEthF-E1-3xE1(12),cf1xEthF-E1-4xE1(13), cf1xEthF-E1-5xE1(14),cf1xEthF-E1-6xE1(15),cf1xEthF-E1-7xE1(16),cf1xEthF-E1-8xE1(17), cf1xEthF(18), cf1xEthF-1xE1(19),cf1xEthF-2xE1(20),cf1xEthF-3xE1(21),cf1xEthF-4xE1(22), cf1xEthF-5xE1(23),cf1xEthF-6xE1(24),cf1xEthF-7xE1(25),cf1xEthF-8xE1(26), cf2xFEth(27),cf2xFEth-1xE1(28), cf4xFEth-2xE1(29), cf2xGEth(30),cf2xGEth-SFP100(31),cf2xGEth-SFP1000(32),cf2xGEth-SFPSG(33) } ACCESS read-only STATUS mandatory DESCRIPTION "IDU configuration." ::= { alR-General 2 } alRStatus OBJECT-TYPE SYNTAX INTEGER { offline(0),ok(1),warning(2),error(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Station alarm status." ::= { alR-General 3 } alRHistory OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "History alarm status." ::= { alR-General 4 } alRIAISL OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Automatic AIS ignored." ::= { alR-General 5 } alRILEVPWR OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Low RX or TX level alarms ignored." ::= { alR-General 6 } alR-ODU OBJECT IDENTIFIER ::= { remote-station 2 } alRRX-Level OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Signal receiver level." ::= { alR-ODU 1 } alRTX-PWR OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Transmitter power level." ::= { alR-ODU 2 } alRMode-TX OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),manual(1),atpc(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Mode of power control." ::= { alR-ODU 3 } alRODU-LB OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU line-loopback." ::= { alR-ODU 4 } alR-Modem OBJECT IDENTIFIER ::= { remote-station 3 } alRQuality OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),out(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Quality of 4-level modulation." ::= { alR-Modem 1 } alR-Supply OBJECT IDENTIFIER ::= { remote-station 4 } alRVoltage-5V OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),high(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage 5V high." ::= { alR-Supply 1 } alRVoltage-5Vor15V OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage 5V or 15V low." ::= { alR-Supply 2 } alRVoltage-24V OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Voltage 24V low." ::= { alR-Supply 3 } alRCurrent-ODU OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),out(1) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU current range." ::= { alR-Supply 4 } alRInput OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Input voltage low." ::= { alR-Supply 5 } alR-IDU OBJECT IDENTIFIER ::= { remote-station 5 } alREEPROM OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "EEPROM memory status." ::= { alR-IDU 1 } alRRAM OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "RAM memory status." ::= { alR-IDU 2 } alRBattery OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "RAM backup battery voltage." ::= { alR-IDU 3 } alRCommIDU OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication status with blocks of IDU." ::= { alR-IDU 4 } alRCommRMT OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication status with remote station." ::= { alR-IDU 5 } alR-MUX OBJECT IDENTIFIER ::= { remote-station 6 } alRBER-10E6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "BER > 10E-6." ::= { alR-MUX 1 } alRBER-10E4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "BER > 10E-4." ::= { alR-MUX 2 } alRFrame OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),loss(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Frame LOSS." ::= { alR-MUX 3 } alR-PDH1 OBJECT IDENTIFIER ::= { remote-station 7 } alRPDHFrame OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),loss(1) } ACCESS read-only STATUS mandatory DESCRIPTION "PDH1 frame LOSS." ::= { alR-PDH1 1 } alRAISPDH OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to frame PDH1." ::= { alR-PDH1 2 } alRLLBPDH OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on PDH1 frame." ::= { alR-PDH1 3 } alRRLBPDH OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on PDH1 frame." ::= { alR-PDH1 4 } alR-Line1 OBJECT IDENTIFIER ::= { remote-station 9 } alRLOSS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 1." ::= { alR-Line1 1 } alRILOSS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 1." ::= { alR-Line1 2 } alRAIS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 1." ::= { alR-Line1 3 } alRAISL1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 1." ::= { alR-Line1 4 } alRLLB1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 1." ::= { alR-Line1 5 } alRRLB1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 1." ::= { alR-Line1 6 } alR-Line2 OBJECT IDENTIFIER ::= { remote-station 10 } alRLOSS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 2." ::= { alR-Line2 1 } alRILOSS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 2." ::= { alR-Line2 2 } alRAIS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 2." ::= { alR-Line2 3 } alRAISL2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 2." ::= { alR-Line2 4 } alRLLB2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 2." ::= { alR-Line2 5 } alRRLB2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 2." ::= { alR-Line2 6 } alR-Line3 OBJECT IDENTIFIER ::= { remote-station 11 } alRLOSS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 3." ::= { alR-Line3 1 } alRILOSS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 3." ::= { alR-Line3 2 } alRAIS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 3." ::= { alR-Line3 3 } alRAISL3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 3." ::= { alR-Line3 4 } alRLLB3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 3." ::= { alR-Line3 5 } alRRLB3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 3." ::= { alR-Line3 6 } alR-Line4 OBJECT IDENTIFIER ::= { remote-station 12 } alRLOSS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 4." ::= { alR-Line4 1 } alRILOSS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 4." ::= { alR-Line4 2 } alRAIS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 4." ::= { alR-Line4 3 } alRAISL4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 4." ::= { alR-Line4 4 } alRLLB4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 4." ::= { alR-Line4 5 } alRRLB4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 4." ::= { alR-Line4 6 } alR-Line5 OBJECT IDENTIFIER ::= { remote-station 13 } alRLOSS5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 5." ::= { alR-Line5 1 } alRILOSS5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 5." ::= { alR-Line5 2 } alRAIS5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 5." ::= { alR-Line5 3 } alRAISL5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 5." ::= { alR-Line5 4 } alRLLB5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 5." ::= { alR-Line5 5 } alRRLB5 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 5." ::= { alR-Line5 6 } alR-Line6 OBJECT IDENTIFIER ::= { remote-station 14 } alRLOSS6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 6." ::= { alR-Line6 1 } alRILOSS6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 6." ::= { alR-Line6 2 } alRAIS6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 6." ::= { alR-Line6 3 } alRAISL6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 6." ::= { alR-Line6 4 } alRLLB6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 6." ::= { alR-Line6 5 } alRRLB6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 6." ::= { alR-Line6 6 } alR-Line7 OBJECT IDENTIFIER ::= { remote-station 15 } alRLOSS7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 7." ::= { alR-Line7 1 } alRILOSS7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 7." ::= { alR-Line7 2 } alRAIS7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 7." ::= { alR-Line7 3 } alRAISL7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 7." ::= { alR-Line7 4 } alRLLB7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 7." ::= { alR-Line7 5 } alRRLB7 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 7." ::= { alR-Line7 6 } alR-Line8 OBJECT IDENTIFIER ::= { remote-station 16 } alRLOSS8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 8." ::= { alR-Line8 1 } alRILOSS8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 8." ::= { alR-Line8 2 } alRAIS8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 8." ::= { alR-Line8 3 } alRAISL8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 8." ::= { alR-Line8 4 } alRLLB8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 8." ::= { alR-Line8 5 } alRRLB8 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 8." ::= { alR-Line8 6 } alR-Line9 OBJECT IDENTIFIER ::= { remote-station 17 } alRLOSS9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 9." ::= { alR-Line9 1 } alRILOSS9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 9." ::= { alR-Line9 2 } alRAIS9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 9." ::= { alR-Line9 3 } alRAISL9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 9." ::= { alR-Line9 4 } alRLLB9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 9." ::= { alR-Line9 5 } alRRLB9 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 9." ::= { alR-Line9 6 } alR-Line10 OBJECT IDENTIFIER ::= { remote-station 18 } alRLOSS10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 10." ::= { alR-Line10 1 } alRILOSS10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 10." ::= { alR-Line10 2 } alRAIS10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 10." ::= { alR-Line10 3 } alRAISL10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 10." ::= { alR-Line10 4 } alRLLB10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 10." ::= { alR-Line10 5 } alRRLB10 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 10." ::= { alR-Line10 6 } alR-Line11 OBJECT IDENTIFIER ::= { remote-station 19 } alRLOSS11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 11." ::= { alR-Line11 1 } alRILOSS11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 11." ::= { alR-Line11 2 } alRAIS11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 11." ::= { alR-Line11 3 } alRAISL11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 11." ::= { alR-Line11 4 } alRLLB11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 11." ::= { alR-Line11 5 } alRRLB11 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 11." ::= { alR-Line11 6 } alR-Line12 OBJECT IDENTIFIER ::= { remote-station 20 } alRLOSS12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 12." ::= { alR-Line12 1 } alRILOSS12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 12." ::= { alR-Line12 2 } alRAIS12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 12." ::= { alR-Line12 3 } alRAISL12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 12." ::= { alR-Line12 4 } alRLLB12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 12." ::= { alR-Line12 5 } alRRLB12 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 12." ::= { alR-Line12 6 } alRRLTrap OBJECT IDENTIFIER ::= { alRADIO-RELAY-LINK 4 } alLast-Message OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Message giving more detailed information on change of alarms status." ::= { alRRLTrap 1 } traps OBJECT IDENTIFIER ::= { alcoma 0 } generalOFF OBJECT IDENTIFIER ::= { traps 1 } generalOK OBJECT IDENTIFIER ::= { traps 2 } generalWAR OBJECT IDENTIFIER ::= { traps 3 } generalERR OBJECT IDENTIFIER ::= { traps 4 } receiverLowAlarmOn OBJECT IDENTIFIER ::= { traps 5 } receiverLowAlarmOff OBJECT IDENTIFIER ::= { traps 6 } transmitterLowAlarmOn OBJECT IDENTIFIER ::= { traps 7 } transmitterLowAlarmOff OBJECT IDENTIFIER ::= { traps 8 } signalQualityAlarmOn OBJECT IDENTIFIER ::= { traps 9 } signalQualityAlarmOff OBJECT IDENTIFIER ::= { traps 10 } ber6EAlarmOn OBJECT IDENTIFIER ::= { traps 11 } ber6EAlarmOff OBJECT IDENTIFIER ::= { traps 12 } ber4EAlarmOn OBJECT IDENTIFIER ::= { traps 13 } ber4EAlarmOff OBJECT IDENTIFIER ::= { traps 14 } inputSupplyAlarmOn OBJECT IDENTIFIER ::= { traps 15 } inputSupplyAlarmOff OBJECT IDENTIFIER ::= { traps 16 } aisFromLineAlarmOn OBJECT IDENTIFIER ::= { traps 17 } aisFromLineAlarmOff OBJECT IDENTIFIER ::= { traps 18 } aisToLineAlarmOn OBJECT IDENTIFIER ::= { traps 19 } aisToLineAlarmOff OBJECT IDENTIFIER ::= { traps 20 } aisToPdhAlarmOn OBJECT IDENTIFIER ::= { traps 21 } aisToPdhAlarmOff OBJECT IDENTIFIER ::= { traps 22 } lossAtLineAlarmOn OBJECT IDENTIFIER ::= { traps 23 } lossAtLineAlarmOff OBJECT IDENTIFIER ::= { traps 24 } lossAtPdhAlarmOn OBJECT IDENTIFIER ::= { traps 25 } lossAtPdhAlarmOff OBJECT IDENTIFIER ::= { traps 26 } lossAtFrameAlarmOn OBJECT IDENTIFIER ::= { traps 27 } lossAtFrameAlarmOff OBJECT IDENTIFIER ::= { traps 28 } trapParam OBJECT IDENTIFIER ::= { alNMS 1 } nmsTrapTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Time of alarms scan." ::= { trapParam 1 } trapSequence OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Number of trap sequence." ::= { trapParam 2 } mwRouteID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Identification of microwave route." ::= { trapParam 3 } stationID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Identification of Radio Relay Link station." ::= { trapParam 4 } stationName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Name of Radio Relay Link station." ::= { trapParam 5 } mgmtGWaddr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "IP address of Management Gateway." ::= { trapParam 6 } lineID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Line ID number." ::= { trapParam 7 } alMPStatusLED OBJECT IDENTIFIER ::= { alMP 1 } alMPEHW OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Hardware error." ::= { alMPStatusLED 1 } alMPESR OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Signal error in radio." ::= { alMPStatusLED 2 } alMPESL OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Signal error on lines." ::= { alMPStatusLED 3 } alMPCA OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Non-standard command activate." ::= { alMPStatusLED 4 } alMPGeneral OBJECT IDENTIFIER ::= { alMP 2 } alMPSupervisor OBJECT-TYPE SYNTAX INTEGER { offline(-1),none(0),terminal(1),local(2),network(3),service(4),alcoma(5) } ACCESS read-only STATUS mandatory DESCRIPTION "Active supervisor." ::= { alMPGeneral 1 } alMPConfiguration OBJECT-TYPE SYNTAX INTEGER { offline(-1),undefined(0),cf2xE1(1),cf4xE1(2),cf1xE2(3),cf1xE1-Ethernet(4),cf1xE3-E1(7),cf1xEthernet(8), cf1xEthF-E1(9), cf1xEthF-E1-1xE1(10),cf1xEthF-E1-2xE1(11),cf1xEthF-E1-3xE1(12),cf1xEthF-E1-4xE1(13), cf1xEthF-E1-5xE1(14),cf1xEthF-E1-6xE1(15),cf1xEthF-E1-7xE1(16),cf1xEthF-E1-8xE1(17), cf1xEthF(18), cf1xEthF-1xE1(19),cf1xEthF-2xE1(20),cf1xEthF-3xE1(21),cf1xEthF-4xE1(22), cf1xEthF-5xE1(23),cf1xEthF-6xE1(24),cf1xEthF-7xE1(25),cf1xEthF-8xE1(26), cf2xFEth(27),cf2xFEth-1xE1(28), cf4xFEth-2xE1(29), cf2xGEth(30),cf2xGEth-SFP100(31),cf2xGEth-SFP1000(32),cf2xGEth-SFPSG(33) } ACCESS read-only STATUS mandatory DESCRIPTION "IDU configuration." ::= { alMPGeneral 2 } alMPStatus OBJECT-TYPE SYNTAX INTEGER { offline(0),ok(1),warning(2),error(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Station alarm status." ::= { alMPGeneral 3 } alMPHistory OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "History alarm status." ::= { alMPGeneral 4 } alMPIAISL OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Automatic AIS ignored." ::= { alMPGeneral 5 } alMPILEVPWR OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Low RX or TX level alarms ignored." ::= { alMPGeneral 6 } alMPODU OBJECT IDENTIFIER ::= { alMP 3 } alMPTuneTX OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Transmitter frequency [MHz]." ::= { alMPODU 1 } alMPTuneRX OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Receiver frequency [MHz]." ::= { alMPODU 2 } alMPTX-PWR OBJECT-TYPE SYNTAX INTEGER { offline(-128) } ACCESS read-only STATUS mandatory DESCRIPTION "Transmitter power level [dB]." ::= { alMPODU 3 } alMPRX-Level OBJECT-TYPE SYNTAX INTEGER { offline(-128) } ACCESS read-only STATUS mandatory DESCRIPTION "Signal receiver level [dB]." ::= { alMPODU 4 } alMPTX-PWRAlrm OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),out(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm transmitter power level." ::= { alMPODU 5 } alMPRX-LevelAlrm OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm signal receiver level." ::= { alMPODU 6 } alMPMode-TX OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),manual(1),atpc(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Mode of power control." ::= { alMPODU 7 } alMPODU-LB OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "ODU line-loopback." ::= { alMPODU 8 } alMPTemperature OBJECT-TYPE SYNTAX INTEGER { offline(-1) } ACCESS read-only STATUS mandatory DESCRIPTION "Temperature ODU." ::= { alMPODU 9 } alMPModem OBJECT IDENTIFIER ::= { alMP 4 } alMPQuality OBJECT-TYPE SYNTAX INTEGER { offline(-1) } ACCESS read-only STATUS mandatory DESCRIPTION "Quality of signal." ::= { alMPModem 1 } alMPSNR OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Signal noise ratio." ::= { alMPModem 2 } alMPQualityAlrm OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),out(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm quality of signal." ::= { alMPModem 3 } alMPSNRAlrm OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Alarm signal noise ratio." ::= { alMPModem 4 } alMPRate OBJECT-TYPE SYNTAX INTEGER { offline(-1),ndef(0),r4Mbps(1),r8Mbps1(2),r16Mbps1(3),r40Mbps1(5),r20Mbps1(6),r10Mbps1(7),r5Mbps1(8), r16Mbps-r2(11),r32Mbps2(12),r40Mbps2(13),r20Mbps2(14),r10Mbps2(15),r5Mbps2(16),r60Mbps(17),r30Mbps(18), r16Mbps2(19),r8Mbps(20),r80Mbps(21),r40Mbps3(22),r20Mbps3(23),r10Mbps3(24),r50Mbps(25),r70Mbps(26), r100Mbps(27),r120Mbps(28),r160Mbps(29),r170Mbps(30),r75Mbps(31),r35Mbps(32),r25Mbps(33),r165Mbps(34) } ACCESS read-only STATUS mandatory DESCRIPTION "Transmision rate of link." ::= { alMPModem 5 } alMPQAM OBJECT-TYPE SYNTAX INTEGER { offline(-1),ndef(0),mp4FSK(1),mpQPSK(2),mp4QAM1(3),mp8QAM(4),mp16QAM1(5),mp4QAM2(6),mp16QAM2(7),mp32QAM(8),mp64QAM(9),mp128QAM(10),mp256QAM(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Low transnission rate of link." ::= { alMPModem 6 } alMPActiveACM OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Activation ACM." ::= { alMPModem 7 } alMPStatusACM OBJECT-TYPE SYNTAX INTEGER { offline(-1),normal(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual ACM status." ::= { alMPModem 8 } alMPSupply OBJECT IDENTIFIER ::= { alMP 5 } alMPInput OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),low(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Input voltage low." ::= { alMPSupply 1 } alMPRDG OBJECT IDENTIFIER ::= { alMP 6 } alMPEEPROM OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "EEPROM memory status." ::= { alMPRDG 1 } alMPRAM OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),bad(1) } ACCESS read-only STATUS mandatory DESCRIPTION "RAM memory status." ::= { alMPRDG 2 } alMPCommRMT OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),error(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication status with remote station." ::= { alMPRDG 3 } alMPMUX OBJECT IDENTIFIER ::= { alMP 7 } alMPBER OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) ACCESS read-only STATUS mandatory DESCRIPTION "Value of BER." ::= { alMPMUX 1 } alMPBER-10E6 OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "BER > 10E-6." ::= { alMPMUX 2 } alMPBER-10E4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),no(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "BER > 10E-4." ::= { alMPMUX 3 } alMPFrame OBJECT-TYPE SYNTAX INTEGER { offline(-1),ok(0),loss(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Frame LOSS." ::= { alMPMUX 4 } alMPLine1 OBJECT IDENTIFIER ::= { alMP 8 } alMPLOSS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 1." ::= { alMPLine1 1 } alMPILOSS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 1." ::= { alMPLine1 2 } alMPAIS1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS to line 1." ::= { alMPLine1 3 } alMPAISL1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "AIS from line 1." ::= { alMPLine1 4 } alMPLLB1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Line loopback on line 1." ::= { alMPLine1 5 } alMPRLB1 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Radio loopback on line 1." ::= { alMPLine1 6 } alMPLine2 OBJECT IDENTIFIER ::= { alMP 9 } alMPLOSS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 2." ::= { alMPLine2 1 } alMPILOSS2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 2." ::= { alMPLine2 2 } alMPLink2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),down(0),up(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Link status line 2." ::= { alMPLine2 3 } alMPSpeed2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),e10Mbps(0),e100Mbps(1),e1000Mbps(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Speed of line 2." ::= { alMPLine2 4 } alMPType2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),halfduplex(0),fullduplex(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication type of line 2." ::= { alMPLine2 5 } alMPFlow2 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Flow control of line 2." ::= { alMPLine2 6 } alMPPktRX2 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Received packets count of line 2." ::= { alMPLine2 7 } alMPByteRX2 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Received bytes count of line 2." ::= { alMPLine2 8 } alMPPktTX2 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted packets count of line 2." ::= { alMPLine2 9 } alMPByteTX2 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted bytes count of line 2." ::= { alMPLine2 10 } alMPError2 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Error count of line 2." ::= { alMPLine2 11 } alMPCollision2 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Collision count of line 2." ::= { alMPLine2 12 } alMPLine3 OBJECT IDENTIFIER ::= { alMP 10 } alMPLOSS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 3." ::= { alMPLine3 1 } alMPILOSS3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 3." ::= { alMPLine3 2 } alMPLink3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),down(0),up(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Link status line 3." ::= { alMPLine3 3 } alMPSpeed3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),e10Mbps(0),e100Mbps(1),e1000Mbps(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Speed of line 3." ::= { alMPLine3 4 } alMPType3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),halfduplex(0),fullduplex(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication type of line 3." ::= { alMPLine3 5 } alMPFlow3 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Flow control of line 3." ::= { alMPLine3 6 } alMPPktRX3 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Received packets count of line 3." ::= { alMPLine3 7 } alMPByteRX3 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Received bytes count of line 3." ::= { alMPLine3 8 } alMPPktTX3 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted packets count of line 3." ::= { alMPLine3 9 } alMPByteTX3 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted bytes count of line 3." ::= { alMPLine3 10 } alMPError3 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Error count of line 3." ::= { alMPLine3 11 } alMPCollision3 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Collision count of line 3." ::= { alMPLine3 12 } alMPLine4 OBJECT IDENTIFIER ::= { alMP 11 } alMPLOSS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),not(0),yes(1) } ACCESS read-only STATUS mandatory DESCRIPTION "LOSS on line 4." ::= { alMPLine4 1 } alMPILOSS4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Ignore LOSS on line 4." ::= { alMPLine4 2 } alMPLink4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),down(0),up(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Link status line 4." ::= { alMPLine4 3 } alMPSpeed4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),e10Mbps(0),e100Mbps(1),e1000Mbps(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Speed of line 4." ::= { alMPLine4 4 } alMPType4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),halfduplex(0),fullduplex(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Communication type of line 4." ::= { alMPLine4 5 } alMPFlow4 OBJECT-TYPE SYNTAX INTEGER { offline(-1),off(0),on(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Flow control of line 4." ::= { alMPLine4 6 } alMPPktRX4 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Received packets count of line 4." ::= { alMPLine4 7 } alMPByteRX4 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Received bytes count of line 4." ::= { alMPLine4 8 } alMPPktTX4 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted packets count of line 4." ::= { alMPLine4 9 } alMPByteTX4 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Transmitted bytes count of line 4." ::= { alMPLine4 10 } alMPError4 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Error count of line 4." ::= { alMPLine4 11 } alMPCollision4 OBJECT-TYPE SYNTAX Unsigned32 ACCESS read-only STATUS mandatory DESCRIPTION "Collision count of line 4." ::= { alMPLine4 12 } END